Operation Manual
Electrical system
9
92 Caravan - 12-11 - EN
When the transformer/rectifier is subject to a heavy load, the fitted charger module
reduces the charging current. This protects the charging device against over-
heating. The transformer/rectifier is subject to a heavy load when e.g. an empty
living area battery is charged, additional electrical appliances are turned on and the
ambient temperatures are high.
Location Depending on the model, the transformer/rectifier is situated either in the bench
or in the bedding box.
9.5.1 Battery selector switch
The battery selector switch is used to set the charger module in the transformer/
rectifier to the type of living area battery installed in the vehicle ("lead acid" or "dry-
fill" battery).
9.5.2 Charging the battery
During driving the towing vehicle generator charges the living area battery. If the
engine of the towing vehicle is switched off, the transformer/rectifier separates the
starter battery of the towing vehicle from the living area battery so that discharging
of the starter battery of the towing vehicle through usage of 12 V living area appli-
ances is not possible.
When the vehicle is connected to the 230 V supply, the transformer/rectifier
charges the living area battery.
9.6 Panel LT 109 (Power Pack SE)
Z Further information can be obtained from the separate instruction manual
"Transformer/rectifier".
X If the battery selector switch is set incorrectly, oxyhydrogen gas (exploding
gas) can form. Danger of explosion!
Z Incorrect setting of the battery selector switch damages the living area battery.
Z Do not change the factory setting of the battery selector switch.
Z The power supply unit is not used to charge the starter battery of the towing
vehicle.
Fig. 93 Panel LT 109
1 12 V main switch
2 12 V indicator lamp
3 Battery charging condition indicator
4 Rocker switch for battery display
5 Tank volume indicator
6 Rocker switch for tank level indicator
12V Batterie Tank
EIN
AUS
1 2 3 4 5 6