Operation Manual

Troubleshooting
15
188 Caravan - 12-11 - EN
15.7.3 Dometic 8 series with MES
9 The gas supply has been cut
off. The flame has not been ig-
nited within 30 seconds in gas
operation mode
z Check the gas supply
z Repeat ignition 3 to 4 times
z Contact customer service
10 The refrigerator is set to 12 V
mode and the vehicle engine
is not running
Start the vehicle engine or se-
lect a different energy source
11 The refrigerator is set to "AU-
TO" mode and no energy
source is available
Provide an energy source and
reset the refrigerator. Switch
the refrigerator off and on
again for this purpose
12 Contact customer service
13 The temperature sensor is de-
fective
Check whether the plug is in-
serted properly above the fin
inside the refrigerator. If so:
Contact customer service
14 The connection between oper-
ating controls and control de-
vice is interrupted
Contact customer service
Z In the case of a fault the LED display fault will always light up " ".
Fault Cause Remedy
LED " " flashes No 240 V power supply Connect 240 V power sup-
ply
240 V automatic circuit
breaker has triggered
Switch on the 240 V auto-
matic circuit breaker
240 V operating voltage
too low
Have the 240 V power sup-
ply checked by an author-
ised specialist workshop
LED " " flashes Fuse on the transformer/
rectifier is defective
Replace fuse on the trans-
former/rectifier
Disconnector relay in the
transformer/rectifier is de-
fective
Contact customer service
12 V operating voltage too
low
Have the 12 V power sup-
ply checked by an author-
ised specialist workshop
LED " " flashes
Lack of gas Open regulator tap and
gas isolator tap
Connect a full gas bottle
Cobwebs or burnt residue
in the burning chamber
Remove the ventilation
grill on the outside of the
vehicle and clean the burn-
ing chamber
Error code Cause Remedy