Operation Manual
Maintenance
13
164 Caravan - 12-11 - EN
Unscrew the screw cap (Fig. 171,1) at the compensator reservoir.
Slowly remove the cover with circulating pump upwards.
Check anti-freeze with an anti-freeze hydrometer. The frost protection content
must be 40% or provide frost protection of up to -25 °C.
Fill the water frost protection mixture slowly into the compensator reservoir.
13.6.3 Bleeding the heating system
The bleeding valves are built in nearby the radiators.
Switch off the hot-water heater and allow it to cool down.
Open the bleeding valve (Fig. 172,1) and leave it open until no more air escapes.
Close bleeding valve.
Repeat this procedure at all bleeding valves.
Check to see if the hot-water heater warms up.
13.7 Air conditioning unit
Z The optimum fluid level is reached when the fluid in the compensator reservoir
is 1 cm above the "MIN" mark.
Fig. 172 Bleeding valve of hot-water
heater
X Prior to carrying out work on the device, turn off the power supply.
Z Never operate the air conditioning unit without a lint filter. Without a lint filter
the evaporator becomes soiled, resulting in the performance of the air condi-
tioning unit being impaired.
Z If the condensation drain is clogged, condensate can enter the vehicle. Keep the
condensation drain free of dirt, leaves and similar obstacles.