Operation Manual

Appliances
10
121Caravan - 12-11 - EN
10.4.4 Reich boiler
The boiler is operated with 230 V. The boiler heats about 5 l of water. The water
temperature can be set on the temperature controller (Fig. 129,1) of the boiler. The
water in the boiler can be heated up to a maximum of 80 °C.
Switching on:
Connect the vehicle to the external 230 V power supply and switch on the 230
V automatic circuit breaker.
Set the desired temperature on the temperature controller (Fig. 129,1). The
indicator lamp (Fig. 129,2) is illuminated during the heating up period.
Switching off:
Turn the temperature controller (Fig. 129,1) in an anticlockwise direction to the
"I" position.
Switching on frost protection:
Turn the temperature controller to the "F" position.
Filling the boiler with water:
Connect the vehicle to the external 230 V power supply and switch on the 230
V automatic circuit breaker.
Set the desired temperature on the temperature controller (Fig. 129,1).
Set all the water taps to "Hot" and open them. The water pump is turned on. The
hot water pipes are filled with water.
Keep the taps open until the water flowing out of the taps has no bubbles in it.
This is the only way to ensure that the boiler is full of water.
Close all water taps.
Emptying the boiler:
Turn the temperature controller (Fig. 129,1) in an anticlockwise direction to the
"I" position.
Open all water taps and set to the central position.
Open the water drainage on the pressure relief valve (Fig. 129,4). To do this turn
the red knob (Fig. 129,3) anticlockwise.
Check whether the water is completely drained from the boiler.
Fig. 129 Reich boiler
Z Further information can be obtained in the manufacturer's instruction manual.