Operation Manual
Appliances
10
117Caravan - 12-11 - EN
10.4 Boiler
10.4.1 Models with waste gas vent on the right-hand side of the vehicle
10.4.2 Truma boiler
Operating modes The boiler has three operating modes:
z Gas operation
z 230 V electrical operation
z Combined operation
The operating mode is set with the operating controls.
The regulation of the water temperature in the boiler is only possible with gas ope-
ration.
X Never let gas escape unburned due to danger of explosion.
X When filling the fuel tank of the towing vehicle, on ferries or in the garage,
never run the boiler in gas operation. Danger of explosion!
X Never operate the boiler in gas operation in closed rooms (e.g. garages).
Danger of poisoning and suffocation!
X The water in the boiler can be heated up to 65 °C. Risk of scalding!
Z When the vehicle is not being used, switch off and drain the boiler.
Z Never use boiler when empty.
Z If the boiler is not being used, empty it if there is any risk of frost.
Z Only operate the boiler with the maximum temperature setting if you require a
large quantity of warm water. This protects the boiler against the build-up of
limescale.
Z Dethleffs recommends that you do not use the water from the boiler as drinking
water.
X If the awning is put up and the boiler is running in gas operation, exhaust
gases from the boiler can escape into the awning area. Danger of suffocation!
Make sure the area is sufficiently ventilated.
X Before starting up the Truma boiler remove the cap from the waste gas vent.