Operation Manual
Appliances
10
114 Caravan - 12-11 - EN
10.3 Air conditioning unit
10.3.1 Air conditioning unit Truma
To execute the individual switching commands, always point the remote control in
the direction of the receiver.
Switching on:
Connect the vehicle to the 240 V power supply. The air conditioning unit is
ready to operate.
Switch on the remote control with the switch (Fig. 121,7). The green indicator
lamp (Fig. 120,1) indicates cooling mode.
Set the desired operating mode with the key (Fig. 121,8).
z"FAN": Only ventilation without cooling.
z"COMFORT": Cooling. The fan output and the room temperature can be set
separately. The green indicator lamp in the receiver indicates the com-
pressor is in operation and therefore cooling mode.
Set the desired fan output and room temperature with the keys (Fig. 121,3 and
4) if necessary. The arrow (Fig. 121,9) indicates the selected setting mode.
If the temperature set on the remote control is reached, the green indicator lamp
goes out, the compressor is switched off and the circulation fan continues to run.
Switching off:
To switch off, press the key (Fig. 121,7) on the remote control again.
Z The air conditioning unit only runs if the vehicle is connected to a 240 V power
supply.
Z The external 240 V power supply must be protected by a fuse of at least 3 A. It is
otherwise not possible to operate the air conditioning unit properly.
Fig. 120 Receiver Fig. 121 Remote control
Z An additional key switch (Fig. 120,2) is on the receiver, which can be used to
switch the air conditioning unit off or on without remote control. If the air con-
ditioning unit is switched on by means of this key switch, the operating mode
set last on the remote control is automatically selected.
Z Condensation accumulates on the vaporiser in cooling mode. To counter-act
any formation of germs, operate the air conditioning unit about 5 to 10 minutes
in the "FAN" and "HIGH" positions to dry the vaporiser.