103Caravan - 12-11 - EN
10.2.2 Trumatic S hot-air heater
Switching on without
automatic ignition:
Open the regulator tap on the gas bottle and the gas isolator tap "Heater".
Turn the control knob on the heater to the required position and press down to
its stop limit.
Strike gas lighting button (at the control knob) several times in succession.
Keep the control knob pressed until the flame burns. You can check in the ins-
pection window in the heater cover whether the flame is burning.
Hold down for a further 10 seconds, until the ignition fuse starts up.
Switching on with automatic
ignition:
Open the regulator tap on the gas bottle and the gas isolator tap "Heater".
Turn the control knob on the heater to the required position and press down to
its stop limit.
The automatic ignition produces ignition sparks. A clicking noise can be heard.
Keep the control knob pressed until the flame burns. You can check in the ins-
pection window in the heater cover whether the flame is burning.
Hold down for a further 10 seconds, until the ignition fuse starts up.
Switching off:
Turn the control knob at the heater to "0". The automatic ignition is switched off
simultaneously.
Close the "Heater" gas isolator tap and the main regulator tap on the gas bottle.
X In case of problems wait for two minutes before trying again.
Fig. 106 Hot-air heater control knob
1
2
3
4
5
6
7
8
9
10
0
Z The automatic ignition sparks until the gas burns. If there is no gas, it will con-
tinue to spark until the battery in the automatic ignition is empty. When the
heater is not required, set the control knob to "0" to avoid the battery in the
automatic ignition running flat.
Z If the clicking noise cannot be heard at all or only in intervals of several seconds
during ignition: Changing the battery on the automatic ignition.
Z Insert new batteries before the beginning of every heating season.
Z Further information can be obtained from the separate instruction manual