Operation Manual

89Caravan - 09-09 - DET-0030-09EN
Gas system
8
Switching off: Set the rocker switch (Fig. 108,2) to " " (Fig. 108,5). The operating indi-
cator (Fig. 108,3) goes out.
Close the regulator taps on the gas bottles (Fig. 107,1 and 4).
Remote display The indicator lamps on the operating unit (Fig. 108) indicate in the vehicle inte-
rior whether the gas bottles are ready for operation.
Indicator lamp "A" (Fig. 108,1): Gas bottle on the central regulator
Indicator lamp "B" (Fig. 108,7): Gas bottle on the switching regulator
Changing gas bottles If an indicator lamp goes out during operation, this signifies that the corre-
sponding gas bottle is empty and must be replaced. The reserve bottle con-
tinues supplying the gas appliances with gas.
Changing gas bottles:
Close the regulator tap on the empty gas bottle.
Unscrew the regulator of the gas bottle.
Connect the full gas bottle to the regulator.
Open the regulator tap on the gas bottle.
Set the knob on the switching regulator with a half-turn, so that the newly
replaced gas bottle will serve as a reserve bottle.
When changing gas bottles, do not smoke or create any open fire.
Always mount the regulator in such a way that the protective cap faces
upwards.