Operation Manual
128 Caravan - 09-09 - DET-0030-09EN
Appliances
10
Switching on: Open the regulator tap on the gas bottle and the gas isolator tap "Cooker".
Open the gas cooker lid.
Turn the control knob (Fig. 149,1) on the burner you wish to use to the igni-
tion position (large flame).
Press the control knob down and hold it.
Light the burner with a gas lighter, a match or other suitable means of
lighting.
Once the flame is burning, the control knob must be held down for 10 to
15 seconds, until the thermocouple automatically keeps the gas supply
open.
Release the control knob and turn to the desired setting.
If ignition is unsuccessful, repeat the entire procedure.
Switching off:
Turn the control knob to the 0-position. The flame fades.
Close the gas isolator tap "Cooker" and the regulator tap on the gas bottle.
10.5.2 Gas oven
Fig. 149 Operating controls for gas
cooker
Keep the ventilation openings on the gas oven open at all times.
There must be no flammable objects near the gas oven when it is being
lit.
The oven flap must remain open when it is being lit.
If ignition has not taken place, repeat the entire procedure. If necessary,
check if there is gas and/or current in the gas oven.
If the gas oven still does not work, close the gas isolator tap and notify
your service centre.
If the burner flame is accidentally extinguished, switch the oven off and
leave the burner off for at least 1 minute. Then ignite it again.
When grilling, pull out the heat guard and leave the flap fully open.
Before using the gas oven for the first time run it for 30 minutes at max-
imum temperature without any contents.
When the flame goes out, the thermocouple automatically cuts the gas
supply.
Further information can be obtained from the separate instruction manual
"Gas oven".