Operation Manual
9
9C
aravan - 09-08 - DET-0030-08EN
Electrical system
9
9.8.2 Power cable for external 240 V connection
Power cable
Three-core (3 x 2.5 mm
2
) flexible rubber sheathed cable
Maximum 25 m in length
1 plug with earth contact
1 socket with earth contact (plug-in devices according to EN 60309)
Connection possibilities For your power cable, we recommend using a CEE connection cable with a
CEE plug and coupling. If this type of connection is not feasible, we recom-
mend the following combination with a safety plug:
Adapter cable:
CEE 17 socket with earth contact (Fig. 111,1) – plug with earth contact
(Fig. 111,2)
Cable reel:
Socket with earth contact (Fig. 111,3) – plug with earth contact (Fig. 111,4)
Adapter cable:
CEE 17 socket with earth contact (Fig. 111,5) – plug with earth contact
(Fig. 111,6)
Depending on the design, the flap for the 240 V connection is designated with
the symbol " ".
Connecting the power
cable:
Open external flap.
Depending on the design, tilt the cover upwards.
Insert connector.
Completely unwind the cable on cable drums to prevent overheating.
Fig. 111 Connection possibilities 240 V
connection
Fig. 112 Connecting an angled con-
nector with socket
When using a CEE 17 angled connector with rear socket (Fig. 112,1)
only use a rubberised and sealed IP 44 socket with earth contact
(Fig. 112,2). Do not use sockets without earth contact (Fig. 112,3).
Danger of electrocution!
Depending on the design, disconnect the connector before removing it.