Operation Manual
9
8 Caravan - 09-08 - DET-0030-08E
N
Electrical system
9
9.7 Panel LT 222
Filling level of the tank The filling level in the water tank can be read off on the panel (Fig. 110).
Displays:
Press rocker switch (Fig. 110,1): One of the indicator lamps (Fig. 110,2) is
illuminated.
9.8 240 V power supply
The 240 V power supply provides electricity for:
sockets with earth contact for appliances with maximum 16 A
refrigerator
12 V living area power supply
The electrical appliances which have been connected to the 12 V power
supply system of the living area are supplied with power from the living area
battery (Power Pack SE) or the power pack.
Connect the vehicle to an external 240 V power supply system as often as
possible. The charger module in the transformer/rectifier automatically
charges the living area battery (Power Pack SE).
9.8.1 240 V connection
The vehicle can be connected to an external 240 V power supply. The cable
may have a length of maximum 25 m.
Fig. 110 Panel LT 222
1 Rocker switch for water tank
2 Water tank indicator lamp
Only allow qualified personnel to work on the electrical system.
The external 240 V power supply must be protected by fuse with a fault
current protection switch (FI-switches, 30 mA).
Always disconnect the electrical connection between the towing vehicle
and the caravan before the caravan is connected to the local power supply.
In order to carry this out, disconnect the plug from towing vehicle socket.
For the connection points on camp sites (camping distributors) highly sen-
sitive fault current protection switches (FI-switches, 30 mA) are obligatory.