Operation Manual
15
1C
aravan - 09-08 - DET-0030-08EN
Sanitary fittings
1
1
Putting into operation: Turn on power supply. The yellow LED (Fig. 177,1) on the panel
(Fig. 176,1) turns on for ca. 1 minute. A vacuum is generated in the system.
If the green LED (Fig. 177,3) on the panel lights up, lift the pedal
(Fig. 176,3) briefly, so that some water runs into the toilet bowl (Fig. 176,2)
and the stopper on the bottom is covered with water.
The vacuum toilet is ready for operation.
Flushing:
Close the lid of the toilet.
Press down the pedal (Fig. 176,3) for several seconds.
Briefly lift the pedal, so that some water runs into the toilet bowl (Fig. 176,2)
and the stopper on the bottom is covered with water.
The red LED (Fig. 177,2) lights up if the cassette must be emptied or removed.
Removing the cassette:
Remove the cassette and empty it as described in sections 11.7.4 and
11.7.5.
11.7.4 Removing the cassette
Open the flap for the cassette on the outside of the vehicle. Insert the key
into the locking cylinder of the push-button lock (Fig. 178,1) and turn a
quarter turn.
Remove the key.
Fig. 176 Vacuum toilet Fig. 177 Vacuum toilet panel
Flushing only functions if the green LED is lit.
The Thetford cassette can only be taken out if the sliding trap is closed.
Fig. 178 Flap for the Thetford cassette Fig. 179 Thetford cassette