Operation Manual
1
22 Caravan - 09-08 - DET-0030-08E
N
Appliances
1
0
Turn the rotary switch (Fig. 139,3) to " " (Fig. 139,5). The green "Opera-
tion" indicator lamp illuminates the knob (Fig. 139,1).
Adjust the knob (Fig. 139,1) to the required water temperature.
The red indicator lamp (Fig. 139,2) illuminates when there is a fault (see
chapter 15).
Switching off:
Turn the rotary switch (Fig. 139,3) to " " (Fig. 139,4).
Close the gas isolator tap "Boiler" and the regulator tap on the gas bottle.
Place cap on waste gas vent.
The red indicator lamp (Fig. 139,2) illuminates when there is a fault (see
chapter 15).
Filling the boiler with water:
Close the drain cock (Fig. 140,2). To do this, set the rocking lever in a hor-
izontal position.
Close the drain cock (Fig. 140,1). To do this turn the cap in a clockwise
direction.
Switch on 12 V power supply on the panel.
Set all the water taps to "Hot" and open them. The water pump is turned
on. The warm water pipes are filled with water.
Keep the taps open until the water flowing out of the taps has no bubbles
in it. This is the only way to ensure that the boiler is full of water.
Close all water taps.
Emptying the boiler:
Turn the rotary switch (Fig. 139,3) to " ".
Turn knob (Fig. 139,1) anticlockwise until it can go no further.
Open boiler drain cock (Fig. 140,2). In order to do this, set the rocking lever
on the boiler drain cock in a vertical position.
Check whether the water has been drained completely from the boiler
(approx. 12.5 litres).
Fig. 140 Drain cocks
Because of the suction effect, a part of the water supply can be also
drained from the lines and the water tank. The water system is however not
completely emptied.
Further information can be obtained from the separate instruction manual