Operation Manual

1
20 Caravan - 09-08 - DET-0030-08E
N
Appliances
1
0
Operating modes The air conditioning unit has the following operating modes:
Automatic
Ventilation, manual
Cooling, manual
Heating, manual
Switching on:
Press the ON/OFF button (Fig. 137,9).
Press the "Mode" button (Fig. 137,11) as often as required until the
required mode (Fig. 137,1, 2, 3 or 4) is indicated on the display
(Fig. 137,20).
Use the "+" (Fig. 137,19) and "–" (Fig. 137,18) buttons to set the desired
temperature.
Use the fan speed button (Fig. 137,10) to select the desired fan level.
Switching off:
Press the ON/OFF button (Fig. 137,9).
LED The LED (Fig. 138,4) on the ceiling unit (Fig. 138,1) displays the operating
status of the air conditioning unit:
Air current The air current can be directed in different directions. The distribution of the air
current toward the front or back is continuously adjustable.
Adjusting air current:
Align the two deflectors (Fig. 138,3 and 5) in the desired position.
Rotate knob (Fig. 138,2) on sliding regulator in an anticlockwise direction.
The sliding regulator for air distribution is released.
Slide the sliding regulator forwards or backwards to the desired position.
The side on which the sliding regulator is located is closed.
Turn the knob tight in the clockwise direction.
Fig. 138 Air conditioning unit (Dometic)
Status LED Signification
Off Air conditioning unit off
Orange Air conditioning unit ready to operate
Green Air conditioning unit in operation
Red (continuous) No 240 V power connection
Red (flashes once intermit-
tently)
Fault in the interior temperature gauge
Red (flashes twice intermit-
tently)
Fault in the exterior temperature gauge