Operation Manual
10
7C
aravan - 09-08 - DET-0030-08EN
Appliances
1
0
10.2.2 Trumatic S hot-air heater
Switching on without
automatic ignition:
Open the regulator tap on the gas bottle and the gas isolator tap "Heater".
Turn control knob on the heater to the required position and press it firmly.
Press gas ignition button (at the control knob) several times in succession.
Keep the control knob pressed until the flame burns. The burning of the
flame can be checked in the inspection window in the heater cover.
Hold the control knob down for a further 10 seconds, until the ignition fuse
starts up.
Switching on with automatic
ignition:
Open the regulator tap on the gas bottle and the gas isolator tap "Heater".
Turn control knob on the heater to the required position and press it firmly.
The automatic ignition produces ignition sparks. A clicking noise can be
heard.
Keep the control knob pressed until the flame burns. The burning of the
flame can be checked in the inspection window in the heater cover.
Hold the control knob down for a further 10 seconds, until the ignition fuse
starts up.
Switching off:
Turn the control knob on the heater to "0". The automatic ignition is
switched off simultaneously.
Close the gas isolator tap "Heater" and the regulator tap on the gas bottle.
In case of problems wait for two minutes before trying again.
Fig. 121 Hot-air heater control knob
The automatic ignition sparks until the gas ignites. If there is no gas, it will
continue to spark until the battery in the automatic ignition is empty. When
the heater is not required, set the control knob to "0" to avoid the battery in
the automatic ignition running flat.
If the clicking noise cannot be heard at all or only in intervals of several sec-
onds during ignition: Change the battery in the automatic ignition.
Insert a new batteries before the start of every heating season.
Further information can be obtained from the separate instruction manual
"Trumatic S".