Fault Cause Remedy
No gas Gas bottle is empty Change gas bottle
Gas isolator tap closed Open the gas isolator tap
Regulator tap on the gas
bottle is closed
Open regulator tap on
the gas bottle
External temperature is
too low (-42 °C for pro-
pane gas, 0 °C for bu-
tane gas)
Wait for higher external
temperatures
Built-in appliance is de-
fective
Contact customer service
Fault Cause Remedy
Ignition fuse does not op-
erate (flame does not
burn after the control
knobs are released)
Heat-up time is too short Keep control knob
pressed for approx. 15 to
20 seconds after ignition
Ignition fuse is defective Contact customer service
Flame extinguishes when
being reduced to its mini-
mum setting
Thermocouple sensor is
incorrectly set
Correctly reset thermo-
couple sensor (do not
bend). The sensor tip
should protrude by 5 mm
beyond the burner. The
sensor neck should not
be more than 3 mm away
from the burner ring; if
necessary, contact cus-
tomer service