Operation Manual
2
18 Motorcaravan - 09-08 - DET-0033-07E
N
Maintenance
1
3
13.5.1 Truma
A lint filter (Fig. 245,1) for the air circulation suction system is at the front of the
air conditioning unit. The lint filter must be cleaned at regular intervals, at least
twice a year however, and replaced if necessary.
The condensation drain is under the floor of the vehicle. Keep the drain hose
free from dirt, leaves or similar to allow the condensation to be drained.
13.5.2 Dometic
A lint filter and an activated carbon filter are each located in the lower part of
the air conditioning system ceiling unit (Fig. 246,2) behind the ventilation grills
(Fig. 246,1 and 3). The lint filters must be cleaned at regular intervals and
replaced if necessary. The manufacturer recommends replacing the activated
carbon filter yearly.
On the left side of the ceiling unit (outside of the vehicle) is located the
drainage opening for the condensation. Keep the drain openings free from dirt,
leaves or similar to allow the condensation to be drained.
13.6 Replacing bulbs and fluorescent tubes
Fig. 245 Air conditioning unit (Truma)
Fig. 246 Air conditioning unit (Dometic)
Bulbs and light fittings can be extremely hot. Therefore, allow lights to
cool down before changing bulbs.
Shut off the power supply on the safety cut-out in the 240 V fuse box
before changing bulbs.
Store bulbs in a safe place inaccessible to children.