1
0
Switching on: Open the regulator tap on the gas bottle and the gas isolator tap "Refriger-
ator".
Press the on/off switch/energy selector switch (Fig. 194,1) down for 2 sec-
onds in order to switch on the appliance. The LED of the operating mode
chosen most recently lights up.
If appropriate press the on/off switch/energy selector switch (Fig. 194,1)
until the gas operating indicator " " lights up. Gas supply is open. Ignition
will take place automatically. A ticking sound can be heard until ignition has
been completed successfully.
Use switch (Fig. 194,6) to adjust refrigerating temperature.
Switching off:
Press down the on/off switch/energy selector switch for 2 seconds. Refrig-
erator is switched off.
Close the gas isolator tap "Refrigerator" and the regulator tap on the gas
bottle.
Electrical operation
The refrigerator can be operated with the following voltages:
240 V AC
12 V DC
Switching the 240 V
operation on:
Press the on/off switch/energy selector switch (Fig. 194,1) down for 2 sec-
onds in order to switch on the appliance. The LED of the operating mode
chosen most recently lights up.
If appropriate press the on/off switch/energy selector switch (Fig. 194,1)
several times until the operating indicator 230 V " " lights up.
Use switch (Fig. 194,6) to adjust refrigerating temperature.
Switching the 240 V
operation off:
Press down the on/off switch/energy selector switch for 2 seconds. Refrig-
erator is switched off.
Fig. 194 Operating controls for the refrigerator (Dometic 8 series with MES)
1 On/off switch/energy selector switch
2 Display-LED "open door" (only for central locking system of the refrigerator door)
3 Display-LED "fault"
4 Operating indicators
5 Display-LED "temperature range"
6 Switch for temperature setting
7 Door opener (only for refrigerator door central locking system)
Close the gas isolator tap "Refrigerator" when the refrigerator is operated