Operation Manual

1
46 Motorcaravan - 09-08 - DET-0033-07E
N
Appliances
1
0
Switching on the heater: Set control knob "Temperature" (Fig. 159,6) on the operating unit to the
desired thermostat setting for the room temperature.
Set rotary switch "Operating mode" (Fig. 159,8) to winter operation "Heater
without boiler" (Fig. 159,2) or to winter operation "Heater and boiler"
(Fig. 159,4).
The indicator lamp "Operation/fault" (Fig. 159,5) lights up green.
Both the symbol of the selected operating mode and the temperature symbol
light red.
Switching the heater off:
Turn rotary switch "Operating mode" (Fig. 159,8) to "OFF" (Fig. 159,10).
After the heater has been switched off, the circulation fan may still run for a
moment in order to cool down the heating appliance.
The indicator lamp "Operation/fault" (Fig. 159,5) goes off.
10.2.6 Alde hot-water heater
The hot-water heater has been fitted below in the wardrobe.
Operating unit The operating unit is divided into two sections:
Display (Fig. 160,1)
Control buttons
Only select the "Heater and boiler" operating mode when the boiler is full
of water.
Further information can be obtained in the manufacturer's instruction
manual.
For further information about the use of the boiler see section "Boiler".
Never run hot-water heater without heating fluid. Observe notes in
chapter 13.
Never drill holes in the floor. This might damage the hot-water pipes.
Do not use the space above and behind the heater as a storage compart-
ment.
The circulating pump must always be turned on when the hot-water heater
is in operation.
We recommend to bleed the heating system after the initial heater opera-
tion and to check the glycol content. Observe notes in chapter 13.
For further information, see the separate instruction manual "Alde Com-
pact" and observe the maintenance instructions found in chapter 13.
For further information about the use of the boiler see section "Boiler".