Operation Manual

1
34 Motorcaravan - 09-08 - DET-0033-07E
N
Electrical system
9
Adapter cable:
CEE 17 socket with earth contact (Fig. 139,1) – plug with earth contact
(Fig. 139,2)
Cable reel:
Socket with earth contact (Fig. 139,3) – plug with earth contact (Fig. 139,4)
Adapter cable:
CEE 17 socket with earth contact (Fig. 139,5) – plug with earth contact
(Fig. 139,6)
Depending on the design, the flap for the 240 V connection is designated with
the symbol " ".
Connecting the power
cable:
Open external flap.
Depending on the design, tilt the cover upwards.
Insert connector.
9.11 Fuses
9.11.1 12 V fuses
The appliances connected to the 12 V power supply in the living area are
fused individually. The fuses are accessible at different positions in the
vehicle.
Fig. 139 Connection possibilities 240 V
connection
Fig. 140 Connecting an angled con-
nector with socket
When using a CEE 17 angled connector with rear socket (Fig. 140,1)
only use a rubberised and sealed IP 44 socket with earth contact
(Fig. 140,2). Do not use sockets without earth contact (Fig. 140,3).
Danger of electrocution!
Depending on the design, disconnect the connector before removing it.
Only replace defective fuses when the cause of the defect is known and
has been remedied.
Replace defective fuses only after the power supply has been turned off.
Never bridge or repair fuses.