Operation Manual
1
88 Caravan - 02-08 - DET-0030-07E
N
Troubleshooting
1
5
15.7 Refrigerator
In the event of a defect contact the nearest customer service workshop of the
relevant appliance manufacturer. The list of addresses is enclosed with the
accompanying appliance documentation. Only authorised qualified personnel
may repair the appliance.
15.8 Dometic air conditioning unit
Fault Cause Remedy
Refrigerator does not
switch on when operating
in 240 V mode
No 240 V power supply Connect 240 V power
supply
240 V automatic circuit
breaker has triggered
Switch on the 240 V au-
tomatic circuit breaker
Refrigerator does not
switch on when operating
in 12 V mode
Contacts on the plug
and/or in the socket have
oxidised and/or are con-
taminated
Clean contacts and spray
with contact spray
Short circuit caused by
water in the plug and/or
socket
Open plug and/or sock-
et, dry out, and spray
with contact spray
Cable interruption on the
plug and/or socket
Open plug and/or sock-
et, re-connect cable
Fuse on power pack or at
transformer/rectifier de-
fective (Power Pack SE)
Replace fuse
Disconnector relay at
transformer/rectifier
(Power Pack SE) defec-
tive
Contact customer service
Refrigerator does not
switch on when operating
in gas mode
The "GAS" operating in-
dicator flashes in yellow
(Dometic 7 series)
Lack of gas Open regulator tap and
gas isolator tap
Connect a full gas bottle
Air in the gas pipe Repeat ignition 3 or
4times
Cobwebs or burnt resi-
due in the burning cham-
ber
Remove the ventilation
grill on the outside of the
vehicle and clean the
burning chamber
Fault Cause Remedy
Air conditioning unit does
not cool
No 240 V power supply Connect 240 V power
supply
Temperature below
16 °C
Temperature has been
set incorrectly
Adjust the temperature
Thermostat defective Contact customer service