Operation Manual

1
00 Caravan - 02-08 - DET-0030-07E
N
Electrical system
9
An intact 12 V fuse can be detected by the unbroken fuse element
(Fig. 113,1). If the fuse element is broken (Fig. 113,2), change the fuse.
Before changing fuses, take the function, value and colour of the relevant
fuses from the following specifications. When changing fuses, only use flat
fuses with the values shown below.
Fig. 113 12 V fuse
1 Unbroken fuse element
2 Broken fuse element
Function Value/colour
Fuses at the living area
battery
(Power Pack SE)
Line from the living area battery to the power supply
unit
40 A red
Line from the living area battery to the power supply
unit
2A grey
Fuse on power pack
(transformer H)
Main fuse 15 A blue
Fuses on power pack
(switched-mode power
supply type I)
Circuit 1 15 A blue
Circuit 2 15 A blue
Circuit 3 15 A blue
Circuit 4 15 A blue
Fuses on power pack
(switched-mode power
supply type II)
Circuit 1 15 A blue
Circuit 2 5 A light brown
Circuit 3 15 A blue
Circuit 4 15 A blue
Fuses on the
transformer/rectifier
EBL 109
(Power Pack SE)
Internal charger 20 A yellow
Booster 15 A blue
Solar 15 A blue
TV 7.5 A brown
Circuit 2 15 A blue
Water pump 5 A light brown
Circuit 1 15 A blue
Refrigerator control 2A grey