8
Unscrew the gas pressure regulator (Fig. 90,3) along with the gas tube
(Fig. 90,5) from the gas bottle with a suitable gas spanner.
Release the fixing belts (Fig. 90,2) and take out the gas bottle.
Place a filled gas bottle in the gas bottle compartment.
Fix gas bottle in place with the fixing belts.
Screw the gas pressure regulator with gas tube on the gas bottle and
secure with a suitable gas spanner (Do not overtighten).
8.5 Gas isolator taps
A gas isolator tap (Fig. 91) for every gas device is built into the vehicle.
The gas isolator taps are located under the cooker or in the vicinity of the gas
devices (e.g. in the bench seat).
8.6 External gas connection
Fig. 91 Symbols for the gas isolator
taps
1 Refrigerator
2Cooker
3 Heater/boiler
4Oven
If the external gas connection is not in use, always close the gas isolator
tap.
Only gas appliances with a suitable adapter should be connected to the
external gas connection.
Connect only external gas appliances which are designed for an opera-
tion pressure of 30 mbar.
Once you have made the connection and opened the gas isolator tap,
make sure that no gas is escaping at the connection point. If there is a
leak in the external gas connection, gas will escape into the open air.
Immediately close the gas isolator tap and the regulator tap on the gas
bottle. Have the external gas connection checked by an authorised spe-
cialist workshop.
When connecting an external gas appliance, make sure that there is
nothing near the external gas connection that could cause a spark.
Do not use the external gas connection to fill gas bottles. Observe the
information stickers on the external gas connection.