1
5
15.4 Gas system
No voltage from the living
area battery (Power Pack
SE)
The living area battery is
discharged
Charge living area bat-
tery immediately
Total discharge
damages the
battery.
If the vehicle is to be laid
up for a long period, fully
charge the living area
battery beforehand
Discharging is caused by
inactive appliances (see
chapter 9)
Extractor hood does not
work
Extractor hood defective Contact customer service
Power pack is defective Contact customer service
Fuse on power pack or at
transformer/rectifier de-
fective (Power Pack SE)
Replace fuse
240 V automatic circuit
breaker has triggered
Switch on the 240 V au-
tomatic circuit breaker
In case of a defect of the gas system (gas odour, high gas consumption)
there is danger of explosion! Close regulator tap on the gas bottle imme-
diately. Open doors and windows and ventilate well.
If the gas system is defective: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.).
Have the defective gas system repaired by an authorised specialist
workshop.
Fault Cause Remedy
No gas Gas bottle is empty Change gas bottle
Gas isolator tap closed Open the gas isolator tap
Regulator tap on the gas
bottle is closed
Open regulator tap on
the gas bottle
External temperature is
too low (-42 °C for pro-
pane gas, 0 °C for bu-
tane gas)
Wait for higher external
temperatures
Built-in appliance is de-
fective
Contact customer service
Fault Cause Remedy