Switching on: Open the regulator tap on the gas bottle and the gas isolator tap "Refriger-
ator".
Set the energy selector switch (Fig. 142,1) to "GAS".
Press the control knob (Fig. 142,2), turn it to the highest level and hold it
down. Wait until gas gets into the burner.
Press the gas ignition switch (Fig. 142,3) repeatedly until the flame
appears in the inspection glass (bottom left in the refrigerator).
Keep control knob (Fig. 142,2) pressed for another 10 to 15 seconds, then
release.
Check in the inspection glass (bottom left-hand side in the refrigerator)
whether the flame is visible.
Adjust the refrigerating temperature with the control knob.
If ignition is unsuccessful, repeat the entire procedure.
Switching off:
Set energy selector switch to " ". Refrigerator is switched off.
Close the gas isolator tap "Refrigerator" and the regulator tap on the gas
bottle.
Electrical operation
The refrigerator can be operated with the following voltages:
240 V AC
12 V DC
Switching the 240 V
operation on:
Set energy selector switch (Fig. 142,1) to "240 V". The operating indicator
lights up green.
Use the control knob (Fig. 142,2) to adjust the refrigerating temperature.
Switching the 240 V
operation off:
Set energy selector switch to " ". Refrigerator is switched off.
Switching the 12 V
operation on:
Set energy selector switch (Fig. 142,1) to "12 V". The operating indicator
lights up green.
Switching the 12 V
operation off:
Set energy selector switch to " ". Refrigerator is switched off.
Fig. 142 Operating controls for the
refrigerator (Dometic 7 series)
1 Energy selector switch
2 Control knob for setting the tempera-
ture
3 Gas ignition button
Close the gas isolator tap "Refrigerator" when the refrigerator is operated