04832 June 27, 2011 Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com INSTALLATION INSTRUCTIONS FOR VALUE SERIESĀ® SURFACE VERTICAL ROD V50/V51 SERIES AND FV50/FV51 SERIES FV50 / V50 x EE FV51 / V51 x EE Delayed Egress L9 = Less 9v Battery SI = Status Indicator "ON" U.S.
Mounting plate Subassembly (BP-2) P/N: 100696-1 or (BP-8) P/N: 100699 Top Latch Assembly P/N 101464 Strike Shim P/N 101067 Top Latch Cover P/N 103545 96 Strike P/N 100330 (FOUND IN MOUNTING PLATE/STRIKE TEMPLATE KIT) 8-32 Screws Bracket is part of Top Latch Assembly 1/4 20 or #14 Screws CENTERCASE MOUNTING PLATE TEMPLATE P/N 100720 LATCH/STRIKE TEMPLATE P/N 101511-1 Top Rod 7' P/N 104051-1 8' P/N 104051-2 10' P/N 103073-1 (FOUND IN MOUNTING PLATE/STRIKE LOCATOR KIT) LOCATING TOOLS USED WITH VALUE
Fastener Table for Surface Vertical Rods Drill Bit Part No.
!!!CHECK BEFORE STARTING!!! Wide Stile (Surface Strike) Minimum door stile 3-1/2" (89 mm) Template drawings provide door and frame structural and dimensional specifications for door and frame preparation. Narrow Stile Minimum door stile 2" (51mm) Doors and frames with walls having a structural thickness (metal skin plus reinforcement, or solid wood) to engage less than (3) full screw threads, are considered unreinforced for hardware.
Approx. 6 inches BP-8 P/N 100699 BP-2 P/N 100696-1 MOUNTING PLATE FOR USE WITH LEVER TRIM -RecommendedMark centerline for unit 40 inches from finished Floor MOUNTING PLATE FOR USE WITH 03 TRIM FIG.
Mark for 96 strike Frame header WIDE STILE Align latch/strike locator with edge of door Mark for 96 strike Mark for top latch Mark for top latch NARROW STILE (NS) Align arrow line with edge of door and frame header 1-1/2" from edge of door (* 2" with tab) 1-1/16" from edge of door Left Hand Reverse shown FIG. 4 Drill holes, #7 for 1/4-20 machine screws, and fasten with 1/4-20x1 PPH machine screws or #14 self drilling screws. For sex nuts drill 3/8" holes.
NOTE: IF TRO DEVICE, SKIP THIS PAGE AND CONTINUE WITH INSTALLATION WIDE STILE Locator placement NARROW STILE (NS) Locator placement Same locator used for top latch Align locator EDGE with door edge and locator bottom with bottom of door or top of threshold if threshold overlaps bottom edge of door. FIG.
Slide endcap assembly onto extrusion CHECKING FOR DEVICE CLEARANCE (Cut-Off procedure if required) Protect wires during cutting Secure with tape Max Cut-Off Length (L) Type 36" Unit 48" Unit Electrified cannot be 6 in Model cut down 2 1 CAUTION: Check device and door frame clearance. If no cut-off needed, proceed to MORTISE CYLINDER INSTALLATION L Cut fillerplate and extrusion to desired length MORTISE CYLINDER INSTALLATION PRECAUTIONARY NOTE: 1.
Procedures for Additional Cut Down Lengths Caution Required-Special Handling Slide endcap assembly onto extrusion Secure with tape 1 CAUTION: Check for device and door frame clearance. 2 REMOVE electronics prior to cut down 4 5 3 Align fillerplate FLUSH to extrusion prior to cut down 6 L Cut fillerplate and extrusion to desired length Battery Reassemble electronics after cutting. Electronics may extend beyond edge of cut fillerplate. 7 Place battery in endcap.
1 2 Slide fillerplate & endcap bracket into extrusion & level pushpad assembly. Note: Endcap Bracket must bottom-out on extrusion. DO NOT REMOVE NYLON SPACER ON BACK OF BRACKET! 3 With pushpad assembly level, secure the endcap bracket to door by tightening the factory installed self-drilling screw. 4 For 1/4-20 machine screws drill #7 holes. For #14 self-drilling screws no pilot holes necessary. For sex nuts drill 3/8" holes.
CORRECT HANDING OF DEVICE NOTE: LINK SHOULD ALWAYS BE IN TOP POSITION Left Hand Reverse (LHR) Right Hand Reverse (RHR) 1/4 20 x 1/4" Screws P/N 101621-5 NOTE HANDING INDICATOR ON CENTER LIFT NOTE: If removed, be sure to replace screws after adjustment. These screws MUST be used. NOTE: If removed, be sure to replace screws after adjustment. These screws MUST be used. LINK FIG.
TOP ROD INSTALLATION (CONT.) Verify top latch bolt is in fully extended position. Rotate bolt for rod height adjustment. Head of bolt should drop freely into slot in carriage. Lock Bolt head firmly in place in Carriage with plate, starwasher and screw. (As shown in detail) FIG. 10 TOP ROD ONLY (TRO) ADJUSTMENT / TROUBLESHOOTING FIG. 10 - Detail TOP LATCH TESTING AND ADJUSTMENT 1. Close the door. The holdback lever should engage the backside of the strike, allowing the latchbolt to extend.
NOTE: IF TRO DEVICE, SKIP THIS PAGE AND CONTINUE TO PAGE 15 NOTE position XX" ( Approx. 37 3/4" Example) To establish bottom rod length, measure the distance from the slot in the carriage to the floor or threshold (XX") and add 5/8". 5/8" BOLT ENGAGEMENT Finished Floor FIG. 10B FIG. 10B - Detail Thread 1/4-20 X 1" hexbolt into rod a MINIMUM of 1/2" Insert rod into bottom bolt. XX + 5/8" Example Align holes in rod and bolt that will result in overall length closest to dimension needed.
Place bottom bolt and rod assembly into bottom bracket. Slide the pin through the slot of the bracket through the bolt and rod assembly. Insert pin clip. Use 1/4 x 20 bolt at top of rod to obtain final adjustment. When properly adjusted, pin will be located at or near the index mark on the bracket. ROD CLIP Lock bolt head firmly in place in carriage with plate, starwasher and screw INDEX MARK FOR 3/4" FROM FLOOR TO BOTTOM OF DOON (UNDERCUT) & THRESHOLD Rotate bolt for minor rod height adjustment.
If additional length is required, remove clip and link pin, move bolt down and reinsert pin in next lower hole. Insert clip on pin. Adjust Bolt for approximately 1/16" clearance between end of bolt and surface of strike when retracted. Open and close door to be sure bolt does not hit high areas of floor. Re-adjust if necessary. Confirm that the bolt drops freely and does not bind when latch is released FIG. 15 BOTTOM LATCH Testing and Adjustment Testing 1.
STANDARD SURFACE VERTICAL INSTALLATION 1. If metal bottom bolt guard is to be used, do not attach the plastic bottom latch cover (refer to bottom bolt guard installation instructions.) 2. If rod covers are to be used, do not install rod guides (refer to rod cover installation instructions). Top latch cover attached with 8-32 x 1/4" PFH screws Place ECL-395-X sign on door Space 1 rod guide equidistant between centercase and latch assemblies (7 foot and 8 foot doors).
EE ELECTRICAL OPTIONS REQUIRES DETEX POWER SUPPLY REQUIRED WIRE SIZES: STRANDED WIRE GAUGE: 18 AWG MIN MAXIMUM LENGTH OF TWO CONDUCTOR CABLE: 40 FEET Power Supply with Detex Delayed Egress device WHITE BLACK GREEN RED BLACK RED BLACK Detex requires one fire alarm relay per power supply Closed Fire Alarm Loop (must be supplied) DETEX REQUIRES THE POWER SUPPLY BE LOCATED WITHIN 40 FEET OF THE DEVICE Fire Loop Sense From (+) terminal to pin #1 on exit device RED/BLK WIRES TO 24 VOLT BLK RED To Exit De
Factory installed jumper EE ELECTRICAL OPTIONS L9= Less 9V battery SI= Status Indicator 1 2 POWER REQUIREMENT: .5 AMPS @ 24 VDC The key cylinder arming switch must be set to "OFF". To prevent the alarm from sounding during installation, attach battery AFTER main power is applied. wer is applied. Delayed Egress Device requires a connection to the Fire Alarm System. The fire alarm connection needs to be made Externally at the Power Supply.
RISER DIAGRAM DETEX FILTERED AND REGULATED POWER SUPPLY WITH FIRE ALARM SYSTEM LOOP 24 VDC @1 AMP MIN PROVIDE WIRING CONDUIT, CONNECTOR, ETC BETWEEN DETEX POWER SUPPLY AND FIRE ALARM CONTROL PANEL AS REQUIRED TO ALLOW THE FIRE ALARM SYSTEM TO OVERRIDE THE DETEX DELAYED EGRESS FEATURE DURING A FIRE ALARM. DETEX REQUIRES THE POWER SUPPLY BE LOCATED WITHIN 40 FEET OF THE DEVICE THE LOSS OF POWER OR OPEN FIRE ALARM CIRCUIT WILL ELIMINATE THE DELAYED EGRESS FUNCTION REQUIREMENTS: MIN.
HARDWIRE TRANSFER OPTIONS (EE models) (Requirements: Minimum 6 Conductor Wires, Maximum 12 Conductor Wires) Electric Hinge Order by finish p/n: EWH8-X Power Transfer Endcap Prep Electric Hinge Endcap Prep Wire chase through door Wire chase through door 1/2" Hole through the inside door face Power Transfer 1/2" Hole through the inside door face p/n: PT-5 Note: For high traffic areas an electric through-wire hinge or power transfer is recommended.
DELAYED EGRESS OPERATIONS PushPad (LHR shown) Red LED Home Key Position Mortise Cylinder Siren Green LED ARMING AND AUTHORIZED EXIT With door closed, insert key in the cylinder, turn CCW, then back to the home key position and remove it. LED glows green. Authorized personnel can exit the door during the arming delay. After a 1, 5 or 15 second arming period, alarm issues three quick beeps and LED goes off, indicating that the unit is armed.
TROUBLESHOOTING Problem Probable Cause Alarm sounds when power is applied: Turn key clockwise to OFF position. No green light when key is turned CCW: Confirm strike is pushing in dead latch. Door must be closed. Confirm 24VDC power on the delayed egress device main board terminals 1(+) & 2(-). Confirm closed fire loop connection on power supply. Confirm cable is plugged in properly. Confirm the mortise cylinder is functioning correctly.
Optional Accessories Glass Bead Kit Catalog No: GB17 through GB21 #1/4-20 X 1-1/2" Self Drilling screws Included Flex Conduit Kit Catalog No: FCV-3 FCV-10 Rod Cover/Bottom Bolt Guard Kit Weatherized FCV-W-3 FCV-W-10 P/N: 103558-1 103558-2 103558-3 103558-4 103558-5 103558-6 103558-7 103558-8 103558-9 V50x84xRCxBG V50x96xRCxBG V50x120xRCxBG V51x84xRC V51x96xRC V51x120xRC V50x84xRC V50x96xRC V50x120xRC Bottom Bolt Guard Kit P/N: 103562 Sex Nut The #10-32 kit is available in (4) finishes: Catalog No: S