Instruction Manual
104852Page9
Low Voltage Activation Connections
You must disconnect all voltage sources before attempting to install an accessory.
THE DETEX, LOW ENERGY AUTOMATIC DOOR OPERATOR, IS TO BE USED WITH
APPROVED SWITCHES.
ContactfactoryforinformationonSensorconnections.
Typicallyyouwilluseawallmounted,hardwiredpushbuttonforactivation.Youmustprovidewire
fromthepushbuttonswitchtotheControlModuleinputs.Knockoutsareavailableontheenclosure
forwireruns.Theconnectionsareterminatedon terminals #1 and #2 of the Control Module.
RefertothediagramincludedwiththeControlModule.
BE SURE ALL WIRING MEETS ALL STATE AND LOCAL CODES.
AlongwithyourDetexLowEnergyAutomaticDoorOperator,youreceivedanInstallationGuidefor
DetexLowEnergyOperatorControlModule,P/N104827.Thisdocumentwillhelpwiththeproper
setup,switchoptionsandwiringschematics.
TheON/OFF/HOLD3-waytoggleswitchhasbeenpre-wiredintotheControlModuleandislocated
atoneendoftheenclosure.
Beforeanyadjustmentscanbemadethefollowingcheckmustbeperformed.Firstthearmmust
beproperlyconnectedtothedoorleaf.ThepowermustbeconnectedandtheswitchintheON
position.Thedoorleafmustbefullyclosed.ExaminetheDoorControl.Thecontrolboardmust
havethreelightsilluminated(LATCH,POWER,andMODULEON).IftheCLOSElightison,review
thearmassemblylocationbymanuallyopeningdoorleafuntilitisstoppedbyinternalstop.Ifthe
doorarmrotateswellbeyond80degreesreferbacktoarminstallationdirections.Ifarmstopsat
approximately80degrees,allowtheleaftoclose.
TheLATCH-CHECKANDBACK-CHECKarecontrolledviathecamontopofthegearbox.Access
isthruthetopoftheoperatorcasedirectlyabovethegearbox.Usinga1/8thinchAllenwrench,
gentlyloosenthescrewthatholdsthecaminplace.Rotatecamintheclosingrotationdirectionuntil
theCLOSElightgoesoutandtheLATCHlightcomeson.Holdingthecaminplacegentlyretighten
theholdingscrew.
DONOTOVERTIGHTENASTHATWILLDAMAGETHECAM.
TesttheLATCH-CHECKpositionbymanuallyopeningthedoorleafuntilyouseeLATCH-CHECK
lightgooutandtheCLOSElightcomeson.Thisshouldbeapproximately4inchesfromJamb.Fine
tuneadjustmentasnecessary.
Ifthelightsfailtoworkcallforfactoryassistance.