User Manual
Installation
Hanger Plate Location for Single or Pair Push Units
Thehangerplateshouldbelocated5/8"fromtheoutsideedgeofthehingejamb,(typical13/4”
frameface)levelandushwiththebottomoftheheaderofthedoorframe.Barclampthe
hangerplate.Usinghangerplate,markanddrillholesintoheaderframe,solidwallorwallstud.
Fastenusingappropriatetypeandsizescrews(Detexrecommendsusingatheadtype).
Note:Drillingdebrisaccumulatedinhangergroovetrackscanpreventtheoperatorfromseating
uniformlywhenmounting.Removedebriswiththinbrush.Maskingtapecanalsobeusedto
preventdebrisfromcollectingingroove.
Lifttheoperatorandlowerontothewebsofthehangerplatebracket.Besurebothtopand
bottomareengaged.
104850Page4
SECURE HANGER WITH SCREWS
HINGED SIDE
5/8”
Oncetheyareseated,pulldownuntilunitiscompletelyushandscrewscanbereplacedin
topcorners.
HangerPlate
Replace
Screw
here
Replace
Screw
here