AWS (Automatic Web Server activation): This setting sets how the configuration web page
will be presented. By default, when viewing this web page, this setting will reset to zero. It is
very important to enter the correct setting in order to enable this configuration web page if
settings need to be changed. Following are valid settings for this parameter and their
descriptions.
1 = Web server will automatically start on next power cycle. This setting will expose
ALL of the MedVue WiFi option card parameters and is not recommended for normal
use.
100 = HTTPS secure web server will be started automatically (same as ‘1’ but using
secure web connection).
200 = HTTPS secure web server will be started automatically (same as ‘201’ below but
using secure web connection).
201 = (RECOMMENDED) HTTP web server will start automatically and will show the
web pages described in this addendum. This is the recommended setting for this
parameter.
LATI (TCP Listening Socket to service remote AT+i commands): This starts a listening
port for remote AT+i commands. This is not recommended for normal operation and should be
set to ‘0’ to disable this functionality.
Once all settings have been entered, click “Submit” at the bottom of the webpage in order to
save the parameters.
It may be necessary after changing parameters to power cycle the weight analyzer for the
settings to take effect.
NOTE: It is important to wait at least 20 seconds before attempting the power cycle
to ensure all settings have been set in the weight analyzer option card.