Product Manual

ERROR AND STATUS DISPLAYS
Display Meaning
ERROR
General error, invalid keypad entry was attempted.
ERR OVERFLOW
Attempting to display a negative number greater than –9,999 or a
positive number greater than 99,999
ERR ZERO LIM
Indicates an attempt to zero a weight outside scale zero range.
Refer to the Calibration Setup ZERO Menu, ZERO LIMIT (Two
Percent Zero Tracking Range Limit) parameter.
ERR UNSTAbLE
Motion is present when MV1 is attempting to perform one of the
following operations: Power Up Zero or Zero Weight Display
OVER CAPACITY
Scale weight exceeds scale capacity.
When the batteries are near the point they need to be replaced
(Alkaline) or recharged (NiCad or NiMH), the battery status
symbol will
not show any bars. If the battery voltage drops too
low for accurate weighing, the MV1 will automatically shut off and
you will be unable to turn it back on.
CAL REQUIREd
Indicates improper stored calibration data. Calibration of MV1 is
required. Consult your scale service representative.
ERR ANALOG
An analog to digital convertor communication error has been
detected. Consult your scale service representative.
ANALOG LOW
The load cell input is below the range of the MV1. Consult your
scale service representative.
ANALOG HI
The load cell input is above the range of the MV1. Consult your
scale service representative.
ERR EEPROM
NOVRAM failure. Consult your scale service representative.
8555-M512-O1 Rev A 03/13
45