10. Turn the power switch, located in the weigh center, to the ON position.
11. If the scale is not level, the indicator will display dashes and NO WEIGHT along with the
out-of-tolerance angle measurements (Pitch and Roll) as a percentage. Pitch refers to the
scale’s rotation front to back and Roll refers to the scale’s motion side to side (front to back
from indicator’s perspective). Using shims may level the scale. If the out-of-tolerance angle
is too great, the scale will need to be moved to a more level location.
12. Inspect all four corners of the scale. Although the scale will weigh properly up to five degrees
off level, individual corners of the scale should not be allowed to teeter. If any of the corners
are not contacting the ground, either move the scale to a more level location or complete
steps 13-15 to install shims.
13. Close the dump valve and turn on the air pump to slightly raise the scale. Once the scale
frame has lifted sufficiently, turn off the pump.
NOTE: If only one side of the scale requires shims to level it, you can close both valves on
that side of the scale and then turn on the air pump to raise that side and not the other side.