European Digital Scale Waist-High Models EU522/EU522HR and Floor Model EU544 Owner’s Manual 0049-M020-O1 Rev C 12/05 CARDINAL SCALE MFG. CO. PO BOX 151 v WEBB CITY, MO 64870 PH (417) 673-4631 v FAX (417) 673-5001 www.detectoscale.
EUROPEAN DECLARATION OF CONFORMITY Manufacturer: Detecto Scale Company Cardinal Scale Manufacturing Company PO Box 151 203 East Daugherty Webb City, Missouri 64870 USA Telephone No. + 417 673 4631 Fax No.
Attachment to the Conformity document DECLARATION OF CONFORMITY with WELMEC 2 paragraph 12 Page 1 of 1 COMPATIBILITY OF MODULES Ref.
Attachment to the Conformity document DECLARATION OF CONFORMITY with WELMEC 2 paragraph 12 Page 1 of 1 COMPATIBILITY OF MODULES Ref.
This page intentionally left blank.
INTRODUCTION Thank you for your purchase of our Detecto European Digital Scale, Waist-High Models EU522 / EU522HR or Floor Model EU544. They were built with Detecto quality and reliability at our factory in Webb City, Missouri, USA. This manual will guide you through installation, and operation of your scale. Please read it thoroughly before attempting to operate this scale and keep it handy for future reference. All rights reserved.
ASSEMBLY Indicator Mounting To install the indicator on the column bracket, push the latch release (on the 758CSV) down flush with the back of the indicator and hold. Next, place the screw heads on the back of the indicator in the large end of the slotted holes in the bracket. Pull down to secure the indicator, and then release the latch release to lock the indicator to the bracket. To remove the indicator from the bracket, reverse this procedure.
OPERATING INSTRUCTIONS Indicator Height Rod Spoon Indicator Platform Height Rod Column Platform Model EU544 Model EU522HR v Install six (6) "C" size batteries (if ordered with scale) in indicator or plug in power supply module. Plug small connector end of power supply cord into power jack located in bottom right corner at the back of indicator. v Set scale on any hard, level, flat surface or low-cut carpet. v With no weight on scale platform, press ON/OFF key to turn indicator on.
HEIGHT ROD INSTALLATION v Remove Height Rod from shipping container. Inspect for signs of damage. Contact our Customer Service Department if necessary. v Remove cardboard insert from height rod. v Place both height rod mount brackets over four (4) pre-installed screws in column and pull down, securing brackets. v Tighten screws as needed. Do not over tighten.
ERROR AND STATUS DISPLAYS Display (1+ A7 A $a % ".3 a ." "%a Meaning Motion is present when attempting to perform one of the following operations: Power Up or Zero Weight Display. Attempting to display a negative number less than -9,999 or a positive number greater than 99,999. Scale weight exceeds scale capacity. Indicates improper stored calibration data, calibration is necessary. The analog to digital circuit has failed. Consult scale serviceman.
SECURITY SEAL INSTALLATION The indicator on the EU522 / EU522HR and EU544 has been designed for attachment of three separate lead-wire security seals. Two seals prohibit access to the calibration switch while a third seal prevents the scale cable from being disconnected from the indicator (see Figure A). Local metrology laws may or may not require these security seals. If your metrology laws require these security seals, follow the directions provided below to install each of the seals. Calibration Seal 1.
PARTS IDENTIFICATION Model EU522 / EU522HR 9 8 3 2 2 TOP VIEW (Cover & Indicator Removed) BOTTOM VIEW 1 6 LEFT SIDE VIEW REAR VIEW 5 7 4 10, 11 10, 11 Model EU544 7
PARTS IDENTIFICATION, Cont. Item Part Number Description 1 1 0049-D027-0A SUB ASSEMBLY: SCALE BASE 2 1 0049-D014-0A SUB ASSEMBLY: EU522HR COLUMN 3 1 593R986 4 1 6013-0045 NUT, HEX 1/4-20 5 2 6021-1426 SCREW, HEX HEAD 1/4-20 X 1.25 6 3 6024-0039 WASHER, LOCK HELICAL 1/4” REG. 7 1 6540-1138 GLIDE 1” BLACK 1/4-20 X 1.5 STUD 8 1 758CSV 9 1 0049-D020-1A 10 2 6013-0026 NUT 1/4-20 HEX ELASTIC STOP/JAM NUT SS 11 2 6021-1531 SCW BUTTON-HD. CAP-SCREW 1/4-20 X 1.
9
10