Product Manual
CONFIGURATION
The scale has been pre-configured at the factory and should not require configuration for
use in most applications. In the event that the factory settings do not meet the
requirements of your application, the following describes the steps to configure the scale.
TO BEGIN CONFIGURATION:
1. Press the ON-OFF / ZERO key to turn on the scale.
2. Press and hold TARE key for 3 seconds.
3. When the display shows
Set
, release the TARE key to enter the
CONFIGURATION mode.
4. The display will change to show
Unit
.
WEIGHING UNITS
To select “kg” (kilogram) weighing units:
1. With the display showing
Unit
, press the HOLD key.
2. The display will change to show “kg” .
3. Press the HOLD key to display kg status.
4. Press the lb/kg key to toggle between:
x
Enable (display will change to
On
) or
x
Disable (display will change to
OFF
).
5. Press the HOLD key.
6. Press the lb/kg key 3 times. The display will change to
Unit
.
7. Proceed to AUTOMATIC SHUTOFF.
To select “lb” (pounds) weighing units
1. With the display showing
Unit
, press the HOLD key and then the lb/kg key. The
display will change to show “lb”.
2. Press the HOLD key to display lb status.
3. Press the lb/kg key to toggle between:
x
Enable (display will change to
On
) or
x
Disable (display will change to
OFF
).
4. Press the HOLD.
5. Press the lb/kg key 2 times. The display will change to
Unit
.
6. Proceed to AUTOMATIC SHUTOFF.
AUTOMATIC SHUTOFF
1. With the display showing
Unit
, press the press lb/kg key. The display will change
to show
AOFF
.
2. Press the HOLD key to begin selection of the automatic shut-off time (in seconds).
The display will change to show
120
.
3. Press the lb/kg key to toggle through the selections, 120, 180, 240, 300, or OFF.
4. When the desired time is displayed, press the HOLD key. The display will change to
show
AOFF
.
5. Proceed to GRAVITY COMPENSATION.
8525-M320-O1 Rev-B x DR660 Operation