User manual

2.2 TOUCHPADS
Eight touchpads on the overhead Control Panel perform all control functions:
2.2.1 STANDBY
When this touchpad is pressed, the unit goes into a low power mode, ready to be returned to full
operation when the OPERATE pad is touched. When STANDBY is displayed on the LCD, the green
READY light is not visible and no processing can take place in the unit. It is important to remember
that the Power Switch located on the Battery Back-up Module (See Section 11.6) should be set to
its OFF position anytime the system is being stored and anytime the system is not in use and is not
connected to AC power for more than 24 hours.
2.2.2 OPERATE
Whenever this touchpad is pressed, the CS 5000 activates all circuits, initiates a self-diagnosis pro-
gram and places the unit in the Operate Mode within fifteen (15) seconds. This diagnostic program
for instant fault detection can be activated at any time by touching this OPERATE pad. If any faults
are ever found, they will be immediately reported on the LCD display. (See Section 4.)
2.2.3 COUNTER
When this touchpad is pressed, the traffic count is displayed on the LCD display. Pressing and hold-
ing this touchpad for ten (10) seconds causes the counter to return to zero (0). Whenever the LCD
is displaying information other than the current traffic count, pressing this touchpad will cause the
count to appear along with the Sequence Number of changes that have been made to
Program/Sensitivity settings. CT (Number) and SEQ (Number) will appear. Each time the
Program/Sensitivity Mode is accessed, the Sequence Code that appears on the LCD will be
advanced one number. It is recommended that a written notation be made on the Operations
Worksheet (see Section 11.1) whenever this code is accessed, explaining reasons for the access.
If the ACCESS touchpad has been pressed and an improper access code has been entered, a * will
appear before the sequence number (SEQ *37). This indicates that an unsuccessful (unauthorized)
attempt has been made to gain access to the Program/Sensitivity setting.
2.2.4 VOLUME
When this touchpad is pressed, the volume level of the unit’s audible alarm will be shown on the
LCD display and the actual volume of the alarm will be heard. The + and - touchpads can be used
by operators to raise or lower the volume. Press OPERATE to return to the operate mode.
CS 5000
User Manual