7. Reconnect the Power Supply Module and Battery Pack Module as shown;
8. Reassemble the system and test.
11.7 STABILIZER BASE INSTALLATION
TOOLS REQUIRED PARTS LIST
•1/4” Electric Drill Motor •2-Mounting Plate
•1/4” (6mm) Nut Driver or Hex Socket •4-Screw #8x2” Self-Tapping 1/4”
•Tape Measure •1-Drill Bit 3/32”
•#2 Phillips Screwdriver •1-Instruction Sheet
Procedure (NOTE: Install mounting plates before assembling the archway)
11.7.1 Examine the location and determine the best routing for the power cord.
11.7.2 For each panel, remove and discard the two (2) rubber bumpers located on the bottom of the pan-
els. these holes will be used for attaching mounting plates to panels.
11.7.3 Using the supplied 3/32” (2.3mm) drill bit, extend the depth of the mounting holes to 2” (50mm) deep.
11.7.4 Attach the plates (with the edges pointing away from the panel using the supplied 2” long screws.
CAUTION:
The power cord must be installed in the correct Panel location (see Page 8, 3.2.2) before the plate
can be secured. DO NOT PINCH the cord between the panel and the plate. Ensure that the head of
the screw is tight against the plate to prevent the panels from sliding.
11.7.5 Assemble the unit.
11.7.6 Place unit in upright position at selected operating location.
11.7.7 Secure the unit to the floor using 1/4” (6mm) mounting screws (not supplied). The mounting holes in
the plates may be used as a drill guide.
CS 5000
User Manual
© 2005 GARRETT METAL DETECTORS 44 PN 1530100 REV E