11.4.2.1 Case I: Use internal power
Disconnect from AC power;
Open Access Door of detection unit;
Remove three (3) screws that hold
controller cover;
Connect the relay or device to control, as
shown at right;
Replace cover and reconnect power.
11.4.2.2 Case II: Use external power
Disconnect from AC power;
Remove three (3) screws that hold
controller cover;
Connect the relay or device to control,
• Replace cover and reconnect power.
11.4.2.3 Case III: External logic control
Disconnect from AC power;
Open Access Door of detection unit;
Remove three (3) screws that hold
controller cover;
Connect the relay or device to control, as
shown at right.
Replace cover and reconnect power.
11.5 REMOTE CONTROL (OPTIONAL)
A complete remote console with all control functions
that are available on the overhead panel is available
for monitoring and controlling functions of the
Magnascanner CS 5000 from a location apart from
the archway.
This remote console is connected to the overhead
unit with telephone-type cable and RJ 45 connectors
which can be easily concealed behind overhead
panels or in 1/2-inch conduit. The remote control
receives its power from the main detector unit.
Pressing a touchpad on the remote console
achieves the same result as pressing the same
touchpad on the overhead panel, except for the
VOLUME and TONE adjustment.
Regulating alarm volume and tone must be done
separately at the remote console and at each unit it
controls. This enables the audio to be set separately
at the required levels for the console and archway.
A 50-foot cable is standard, but custom lengths are
available.