User manual

3. INSTALLATION INSTRUCTIONS
3.1 SITE SELECTION
The Garrett CS 5000 should be located on a level, stable floor with no large metal items within three
(3) feet. Any nearby large metallic object can interfere with operation of the detector. Moving metal-
lic objects, such as an escalator or revolving door, close to the detector can cause false alarms. Such
alarms can also be caused by electrical interference from radio telephones, television monitors, pow-
erful electronic motors and transformers, power cables and control circuits.
Garrett’s special built-in circuitry is designed to suppress much of this electronic noise, especially X-
ray monitor horizontal synchronization signals and closed circuit television. Multiple frequencies per-
mit several CS 5000 units to operate simultaneously, in close proximity.
For information concerning the operation of multiple units, see Section 11.3.
The site for a CS 5000 should be selected with requirements for its pedestrian traffic and use in mind;
i.e. space for waiting lines, operators and areas for hand-scanning. Although the detector is effective
with traffic moving in either direction, best results are obtained when traffic enters from the side oppo-
site to the control touchpads and LCD display.
Locate the archway where it will not be subject to rain, mist or condensation. Protect the power cable
from pedestrian as well as vehicular traffic.
3.2 ASSEMBLY
NOTE: COMPLIANCE WITH REGULATORY STANDARDS REQUIRES THAT A CORD SET BE
USED FOR INSTALLATION.
3.2.1 Lay out the major pieces of the CS 5000, as shown at the right. Make certain all other attach-
mendevices are included. These should include:
• Detection Panel A
Detection Panel B
Detection Unit
Crosspiece
Power Cord
1/4-20x3” Screws (8)
Finishing Washers (8)
Warranty Card
User’s Manual
Operator’s Manual
Instruction Video
Access Code Card
• Cord Set
CS 5000
User Manual
© 2005 GARRETT METAL DETECTORS 12 PN 1530100 REV E