Owner`s manual
8555-M483-O1 Rev B 750 Owner’s
21
SERIAL PRINT COMMANDS
The Serial port on the 750 is a bi-directional port and can receive and transmit data. It can
output to a printer as well as communicate to a computer. Using the serial port, it is possible to
control the printing operation of the 750 by transmitting commands to the indicator.
Journal Mode Print Command
The host device (computer) sends:
<LF> P <CR>
The ticket will be printed (or data transmitted) in the following format:
Weight, BMI, Height
Where:
Weight: xxx.xuu G
BMI: xx.x
Height: x' xx.x”
NOTE: If ID or BMI are disabled, the field will be left out.
Recall Data Queue Command
The host device (computer) sends:
<LF> XS <CR>
The 750 will Recall the Data Queue. The data will be transmitted in the following format:
ID, Weight, Units, Mode<cr><lf>
Where:
ID = xxxxxxxxxxx Up to 11 digit ID number
Weight = xxxxxx.x Six digits with decimal point
Units = uu None, lb, kg, oz, g, st
m = Mode G = Gross
cr = Carriage Return (hex 0D)
lf = Line Feed (hex 0A)
NOTE: Recalling the data queue does not delete the current data. The separate delete
command must be sent to clear the queue.
Delete Data Queue Command
The host device (computer) sends:
<LF> XD <CR>
The 750 will Delete the Data Queue.
Serial Print commands operate the same as pressing Down Arrow ()/PRINT key.
They allow multiple printings, but will only store the values once until the weight goes
below the 1/10 of scale capacity threshold.