Specifications
5.4.5. Test Result
Model Number I-7520A
Test Item Surge
Test Mode Mode 1
Angle 0, 90, 180, 270
Date of Test 2014/02/06 Test Site TE08
Inject
Line
Polarity
Voltage
kV
Time Interval
(Second)
Inject
Method
Performance
Criterion
Result
L+N ± 1 60 Direct A B Pass
L+PE ± 2 60 Direct A B Pass
N+PE ± 2 60 Direct A B Pass
L+N+PE ± 2 60 Direct A B Pass
Note: The testing performed is from lowest level up to the highest level as required by standard, but only highest
level is shown on the report.
Criterion A : Operate as intended during and after the test
Criterion B : Operate as intended after the test
Criterion C : Loss/Error of function
Additional Information
EUT stopped operation and could
/
could not
be reset by operator at kV of
Line
.
No false alarms or other malfunctions were observed during or after the test.
A Test Lab Techno Corp.
Report Number: 1402CE13-01
59 of 153