Specifications

4.4.3. Setup
4.4.4. Test Procedure
The EUT is supplied in series with power analyzer from a power source having the same normal voltage
and frequency as the rated supply voltage and the equipment under test. And the rated voltage at the
supply voltage of EUT of 0.94 times and 1.06 times shall be performed.
The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated to
produce the most unfavorable sequence of voltage changes under normal operating conditions.
During the flick measurement, the measure time shall include that part of whole operation cycle in which
the EUT produce the most unfavorable sequence of voltage changes. The observation period for
short-term flicker indicator is 10 minutes and the observation period for long-term flicker indicator is 2
hours.
A Test Lab Techno Corp.
Report Number: 1402CE13-01
40 of 153