Product Manual

0064-0085-0M Rev B y 6880 Owner’s Manual 35
EVENT COUNTER
The Detecto Model 6880 Rolling Chair Scale has been designed with an Event Counter type of
security seal. When selected, the scale will display two numbers representing the Calibration
and Configuration counters.
Calibration Counter (!)
The calibration counter is incremented when a value in the calibration part of the setup is
changed ($, -0;, 3, *9, -!;, 00#;, '%#, !, 9<, &($). The counter is only
incremented 1 time even if more than one parameter is changed in setup.
Configuration Counter (+)
The configuration counter is incremented when a value in the configuration part of the setup
is changed ($'#, #;9, *9, *9, '*2, (9, 00;, 3(, #'9, 00)0, *, *`;,
6/3). The counter is only incremented 1 time even if more than one parameter is changed
in setup.
To Review the Event Counter:
1. Press the key to turn the scale on.
2. The scale will perform a display test (turn on all segments and annunciators) and then
change to show the software revision for a few seconds.
3. Next, the display will change to the Weight Display with the Æ0Å (ZERO) and [\
(STABLE) annunciators turned on to show a stable, center-of-zero weight condition.
4. Press and hold the key.
5. The display will show height for a brief time, followed by the software revision.
6. Release the key.
7. The display will change to show ! (Calibration Counter) on the small upper seven-
segment display and up to a 3-digit number on the large lower seven-segment display
for approximately two (2) seconds.
8. Next, the display will then show + (Configuration Counter) on the small upper seven-
segment display and up to a 3-digit number on the large lower seven-segment display
for approximately two (2) seconds and then change to show all dashes.
NOTE: If your scale is the Model 6880-C(-AC), additional information for the Wi-Fi
and Bluetooth (BLE) settings will be shown after the Configuration Counter. Refer
to the next section, Display Scale Wi-Fi and Bluetooth Settings for additional
information and instructions.
9. To return to normal operation, press the key or press the key to turn off the scale.