Product Manual

0064-0085-0M Rev B y 6880 Owner’s Manual 15
SCALE SETUP, CONT.
'9# (OIML)
This setting controls the OIML (European) specific requirements.
The display will show '9# and the current setting. If the value displayed is acceptable,
press the
key. Otherwise, press the
×
or
Ø
keys to toggle the OIML selection between
(* or 06e and then press the
key to save it and proceed to the next prompt.
Allowable settings are (* for the EU or 06 for the US.
$'# (Power Up Zero)
The display will show $'# and the current setting. If the value displayed is acceptable,
press the
key. Otherwise, press the
×
or
Ø
keys to toggle the power-up zero between
(* or 06e and then press the
key to save it and proceed to the next prompt.
This setting controls the zeroing of the scale on power-up. If enabled, the scale will be reset
to zero automatically on power-up. Allowable settings are (* or 06.
#;9 (Zero Tracking)
The display will show #;9 and the current setting. If the value displayed is acceptable,
press the
key. Otherwise, press the
×
or
Ø
keys to select a new value and then press
the
key to save it and proceed to the next prompt.
This setting controls the automatic Zero Tracking of the scale. Allowable values are 0 to 10,
indicating the number of half-divisions above or below zero that the scale will attempt to
maintain the zero position. NOTE: Select 0 (zero) to disable Zero Tracking.
*9 (Com1 Mode)
The display will show *9 and the current setting. If the value displayed is acceptable,
press the
key. Otherwise, press the
×
or
Ø
keys to toggle the Com1 Mode between
60; (continuous output), $#!! (weight on demand) and :8#; (Welch-Allyn Spot LXi
interface) then press the key to save it and proceed to the next prompt.
This setting controls the output for Com 1. Allowable settings are 60;, $#!!, or :8#;.
If 60; (continuous output) was selected for Com 1, the scale will continuously transmit
weight data.
If $#!! (Weight-On-Demand) was selected for Com 1, and the scale is connected to a
computer for transmission of weight data to a PC-based EMR (electronic medical record)
software program, it will transmit a single set of weight data each time the computer sends a
weight request “ENQ” (hex 05) or an SMA weight request “W”.
If :86; (Welch-Allyn Spot LXi interface) was selected for Com 1, the scale will
automatically interface to a Welch-Allyn Spot LXi interface device to transmit weight data.
&($
(Select Type of Printer Output – If *% (Com1 Mode) is set to $#//)`
The display will show &($ and the current setting. If the value displayed is acceptable,
press the
key. Otherwise, press the
×
or
Ø
keys to select a new value and then press
the
key to save it and proceed to the next prompt.
Allowable settings are 0 or 1.
0 = Print Ticket 1 = Print Journal Line