Specifications

8200-M242-O1 y 210-FE
Page 1
SPECIFICATIONS
Power Requirements: 90 to 264 VAC (50/60 Hz) at 0.4A
Enclosure Type: NEMA 4X/IP66
Enclosure Size: 9.7" H x 15” W x 3.1” D
(246mm H x 381mm W x 79mm D)
Shipping Weight: 12 lbs / 5.4 kg
Operating Environment: Temperature: 14 to 104 ºF (-10 to +40 ºC)
Humidity: 90% non-condensing (maximum)
Display: Six digit, seven segment, 2.5" high (display)
Three digit, sixteen segment, 0.8” high (annunciators)
Ten level brightness control
Transducer Excitation: 12 VDC
Signal Input Range: 1.0 mV min. to 40 mV max. (with dead load boost)
Number of Load Cells: 8 each, 350 OHM minimum resistance
Load Cell Cable Length: 1500 feet maximum. Consult factory for other requirements
30 feet maximum without sense lines
Division Value: 1, 2, or 5 x 10, 1, 0.1, 0.01, 0.001 commercial
0 to 99, non-commercial
Sensitivity:
NON-COMMERCIAL
NTEP
CANADA
OIML
0.15 uV/e
0.3uV/e (Class III/IIIL)
0.3uV/e (Class III/IIIHD)
0.7 uV/e (Class III)
Scale Divisions:
NON-COMMERCIAL
NTEP
CANADA
OIML
100 to 240,000
100 to 10,000 (Class III/IIIL)
100 to 10,000 (Class III/IIIHD)
100 to 10,000 (Class III)
Internal Resolution: 1 part in 16,777,216
Tare Capacity: Scale Capacity
Sample Rate: 1 to 100 samples per second, selectable
Auto Zero Range: 0.5 or 1 through 9 divisions
Weighing Units: Tons, Pounds, Ounces, Metric Tons, Kilograms, Grams
Keypad: Color coded Membrane type, 22 keys
Standard I/O: (1) bi-directional RS232 (20mA)
(1) output only RS232 (20mA)