Specifications

8200-M242-O1 y 210-FE
Page 16
KEYPAD FUNCTIONS, Cont.
PRINT KEY
Pressing this key will add the displayed gross or net
weight or piece count to the associated accumulator
and initiate the transmission of weight and other data
selected during setup of the Print menu items via the
selected printer output port (see Port= under Print
menu) unless
the continuous data feature of this port
was enabled during setup and calibration.
If the .4? (ID Prompt) has been enabled during setup,
when the PRINT key is pressed, the indicator will
prompt for an ID to be printed on the ticket.
If the a80:? is set to 1 (Yes), input up to 6 digits for the ID and then press the ENTER key
to complete the transaction. The print function will occur after the ENTER key is pressed.
If the a80:? is set to 0 (no), press the ENTER key to display the current ID. If ID
displayed is acceptable, press the ENTER key again to complete transaction. Otherwise,
input up to 6 digits for the ID and then press the ENTER key to complete the transaction.
The print function will occur after the ENTER key is pressed.
NOTE! The indicator will not respond to the Print command unless the weight
display is stable. If displaying gross weight, the only weight printed is gross weight.
If displaying net weight, the gross, tare, and net weights are printed.
Programmable Print Formats
The 210-FE includes support for 2 programmable print formatted tickets in addition to the
standard print tab settings. These tickets
are designed by the Cardinal Scale’s PC based
programs Visual Print or nControl and then downloaded to the indicator.
During operation, the print formats are selected by using the 4 and PRINT keys in
combination (refer to the next section for details). NOTE! When the PRINT key is pressed,
the indicator looks for the selected format. If the selected format is not found, the print tab
settings will be used to print the ticket.
ZERO/REVIEW KEY
This key performs two functions. In normal operation, pressing this key will cause an
immediate zeroing of the weight display up to the selected limit of 4% or 100% of the scale’s
capacity. Note that this selection is made during the setup and calibration of the instrument.
Pressing this key after the 4 key will enter the Review mode of Setup and Calibration. Refer to
description of 4 key and the Setup Review section of this manual for details.
TARE KEY (with diamond "T" symbol)
This is a dual function key. Pressing the TARE key alone (Pushbutton Tare mode) will store
the current gross weight as a new tare weight and cause the weight display to change to the
net weight display mode (1is shown on the annunciator display). Pressing the key after
entering a numeric value (Keypad Tare) will cause the value entered to be accepted as a new
tare weight.
NOTE! Tare weights equal to or greater than scale capacity cannot be entered. In addition,
keypad tare weight division value must be same as scale division value. For example, a
unit with .005 lb as division value will display A::7: if you enter 1.003 for tare weight.
TICKET EXAMPLE
#2
10:19 23/08/2000
100.00 lb G
20.00 lb T
80.00 lb N
0.00 lb GROSS ACCUM
272.00 lb NET ACCUM