Specifications
8200-M242-O1 y 210-FE
Page 11
INSTALLATION, Cont.
Relay Board - (Optional)
The relay board (Cardinal p/n 8539-C062-0A) is mounted in the RB4-F external junction box
for use with the 210-FE indicator. Connect devices to be controlled as shown in Figure No. 8.
The relays must
be configured to be on (closed) or off (open) at weights under the preset
weight then switch at the preset weight from on-to-off or off-to-on by setting the under weight
condition to on or off during setup and calibration or setup review. Refer to the Setup and
Calibration, “4a7=<” (Digital Output) section of this manual for more information.
EXAMPLE: 4a7(<? 1,1
The PWC1 relay is on (closed) for weights under the preset weight and off (open) for weights
equal to or over the preset weight.
NOTE! All relays are the “normally-open” type that will open when power to
indicator is lost.
Figure No. 8