Specifications
8200-M024-O1 Rev H y 205 Installation & Technical
24
SETUP AND CALIBRATION, CONT.
Dual-Point without Zero (False Zero) Calibration
IMPORTANT! The functions of numeric keys are replaced by using the
UNITS/
LEFT ARROW and the ASTERISK/UP ARROW keys. The cursor location is
identified by the blinking character and can be advanced to the left to the next
position by pressing the UNITS/
LEFT ARROW key. Pressing the ASTERISK/UP
ARROW
key will change the blinking character to the next value.
!> – First Calibration Weight
The display will show !>. This is the first of two calibration steps. This weight is
the TEST WEIGHTS / TEST LOAD.
• Place the weights on the scale platform.
• Using the UNITS/
LEFT ARROW and ASTERISK/UP ARROW keys, input the value of the
calibrated test weights / test load, then press the TARE/
ENTER key. NOTE! When
entering values for !>, the digits start displaying on the right side of the display
and proceed to the left. When large values are used (more than 3 digits), the !>
prompt will automatically scroll off the left side of the display to show the additional
digits on the right as they are entered.
• Starting at the left and proceeding right, a series of dashes will appear on the display.
The dashes will stay on the display momentarily, then disappear, after which the
display will show: !>.
!> - Second Calibration Weight
The display will show !>. This is the second of two calibration steps.
• Remove the weights on the scale platform, and then press the NET/GROSS key.
• Starting at the left and proceeding right, a series of dashes will appear on the display.
The dashes will stay on the display momentarily, then disappear, after which the display
will show: *-6.
Single-Point for Span Only (Last Zero) Calibration
!> – First Calibration Weight
The display will show !>. This is the first of two calibration steps. This weight is
the TEST WEIGHTS / TEST LOAD.
• Zero the scale, and then place the weights on the scale platform.
• Using the UNITS/
LEFT ARROW and ASTERISK/UP ARROW keys, input the value of the
calibrated test weights / test load, then press the TARE/
ENTER key. NOTE! When
entering values for !>, the digits start displaying on the right side of the display
and proceed to the left. When large values are used (more than 3 digits), the !>
prompt will automatically scroll off the left side of the display to show the additional
digits on the right as they are entered.
• Starting at the left and proceeding right, a series of dashes will appear on the display.
The dashes will stay on the display momentarily, then disappear, after which the
display will show: !>.
!> - Second Calibration Weight
The display will show !>. This is the second of two calibration steps.
• Remove the weights on the scale platform, and then press the ZERO key.
• The display will advance to *-6.