Specifications
8200-M024-O1 Rev H y 205 Installation & Technical
19
SETUP AND CALIBRATION, CONT.
;9!> (4% Zero Range)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER‘ key again to save it. Otherwise, use the ASTERISK/UP ARROW
key to toggle to a new setting and then press the TARE/ENTER key to save it.
;9!> (Yes) ;9!> (No)
4% of scale capacity Full capacity (no limit)
$'#> (Power-Up Zero Feature)
Press the TARE/
ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/
ENTER‘ key again to save it. Otherwise, use the ASTERISK/UP ARROW key to
toggle to a new setting and then press the TARE/
ENTER key to save it.
$'#> (Yes) $'#> (No)
Automatic Re-Zero on Power-Up No Re-Zero on Power-Up
*!$> (Sleep Mode Feature)
The Sleep Mode feature conserves battery power when the indicator remains unused for a
selected period of time. With the feature enabled, the load cell excitation will be reduced and
the display will be blank.
Press the TARE/
ENTER key to show the current status of this feature. If a number other than 0
is shown, this feature is selected and the number shown corresponds to the number of minutes
of a stable zero weight reading before the indicator enters the sleep mode. If the setting
displayed is acceptable, press the TARE/
ENTER key again to save it. Otherwise, use the
ASTERISK/
UP ARROW key to toggle to a new setting (0 to 10) and then press the TARE/ENTER
key to store the new setting. Note that selecting 0 disables this feature.
`6> (Auto Shutoff)
The Automatic Shutoff feature will automatically turn the indicator off (when it is not in use)
after a predetermined period of inactivity to prolong battery life. To turn the indicator back on
you must press the ON / OFF key.
Press the TARE/
ENTER key to show the current status for this feature. A number other than 0
indicates that the auto shutoff feature is enabled and the displayed number corresponds to the
number of minutes of stable weight displayed before the indicator is turned off automatically.
Note that a 0 indicates the feature has been turned off. If the setting displayed is acceptable,
press the TARE/
ENTER key again to save it. Otherwise, use the ASTERISK/UP ARROW key to
toggle to a new setting (0 to 10) and then press the TARE/
ENTER key to store the new setting.
!;9> (Clear Tare)
The Clear Tare feature allows the indicator to clear the Stored Tare weight when the Net
weight goes below a value greater than 1/2 the stored tare weight or goes below zero (a
negative net weight after display of a positive net weight). With this feature enabled, the
operator must re-set the tare after completion of a transaction when the load (container plus
item) is removed from the scale.
Press the TARE/
ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/
ENTER‘ key again to save it. Otherwise, use the ASTERISK/UP ARROW key to
toggle to a new setting and then press the TARE/
ENTER key to save it.
!;9> (Yes) !;9> (No)
Automatically clears Stored Tare
when Net weight goes below zero
Stored Tare is not cleared when
Net weight goes below zero