Specifications
SETUP AND CALIBRATION, CONT.
Sleep Mode
The display will now show
SLP=
. The Sleep Mode feature also conserves battery power when
the indicator remains unused for a selected period of time. With the feature enabled, the load
cell excitation will be reduced and the display will show
SLEEP
. The Sleep feature requires
that the indicator remain at the center of zero to activate, unlike the Automatic Shutoff feature
which only requires no motion. Weight placed on the scale will activate the indicator and
return it to the weight mode. NOTE! This setting may be revised without having to enter the
calibration mode.
Press the ASTERISK key to show the current setting. To enable, use the UNITS key to select
the number (1 to 9) of minutes (time approximate) of inactivity at zero before the indicator will
enter the Sleep mode. Press the PRINT key to save the setting. Enter a 0 to disable the
Sleep mode. NOTE! This setting may be revised without having to enter the calibration mode.
Baud Rate Selection
The display will now show
bAUd
. Press the ASTERISK key to show the current setting. If
acceptable, press the PRINT key to save it. Otherwise use the UNITS key to select the
desired baud rate and press the PRINT key to save the setting. NOTE! The FACTORY
setting is 3 (9600 baud) and may be revised without having to enter the calibration mode. The
following baud rates are available:
0 = 1200 1 = 2400 2 = 4800 3 = 9600 4 = 19,200 5 = 38,400
Print Ticket Format
The display will now show
Prt=
. Press the ASTERISK key to view the current setting. If
acceptable, press the PRINT key to save it. Otherwise use the UNITS key to change the
selected print ticket format. Allowable values are:
0 = Default Format 1 = nControl Format 1 2 = nControl Format 2
Continuous Output
The display will now show
COnt=
. Press the ASTERISK key to view the current setting. If a 1
(1=YES) is displayed, the feature has been enabled and the 204 will send a continuous output
of weight data to the serial I/0 connector. If a 0 (0=NO) is displayed the data will only be
transmitted when the PRINT key is pressed or on receipt of an ENQ command from a
computer. Press the UNITS key to change between 1 (YES) and 0 (NO). Once the proper
setting is displayed, press the PRINT key to save the setting. NOTE! This setting may be
revised without having to enter the calibration mode.
End-Of-Print Line Feeds
The display will now show
EoP=
. At the end of a data transmission to a printer, the 204 can
send a number of line feed commands to space the paper in the printer to the desired position
for withdrawal or for the next print. Press the ASTERISK key to view the current setting. If the
setting shown is acceptable, press the PRINT key to save it. Otherwise, use the UNITS key to
select the desired number of line feeds (0 to 99). With the desired number displayed, press
the PRINT key to save the setting. NOTE! This setting may be revised without having to enter
the calibration mode.
Done
The indicator display will now show
dOnE
. The setup and calibration process has been
completed. Remove the power from the indicator and re-assemble for use.
8555-M313-O1 Rev G x 204 Installation & Technical
19