User`s guide
- 11 -
This chart explains the procedure for bypassing a faulted zone prior to arming the system.
There may be occasions when it is desirable or necessary to temporarily bypass one or more zones prior to arming the system.
Bypass commands only work when the control panel is disarmed. For instance, an open window may cause the DS7447/
DS7447E display to read “Not Ready” followed by the zone number. The DS7445/DS7445i may have one of its zone 1-16 LEDs
on steady.
If more than one zone requires bypassing, simply enter the additional zone numbers.
Note: See Force Arming for another method of zone bypassing.
The zone number must be entered as a three digit number. Example: 001, 062, 125, etc.
Note: All bypasses are cleared when the system is disarmed, unless they are 24-hour zones.
To clear a bypass on a 24-hour zone, use one of the two methods above.
If bypassing is performed from a Master keypad, you must be in Single Partition Mode.
Zone Bypass
Type of Bypassing
Desired
Command Sequence What will Happen What to Do
Bypass Faulted
Zones
[PIN] + [Bypass] [XXX]
[XXX] [XXX]
(zone numbers)
The Status
light will begin to flash if
no other zones are violated.
Arm control panel, if
desired, after bypassing.
Read Bypassed
Zones
[PIN] + [Bypass]
“
Bypass
” will be displayed on the
DS7447/DS7447E followed by the
zone number of any bypassed
zones. The DS7445/DS7445i will
flash the zone LED (1-16) of any
zone being bypassed.
Clear Individual
Bypassed Zone(s)
[PIN] + [Bypass] [XXX]
(zone numbers)
Individual zone bypasses will be
cleared.
Clear All Bypasses
[PIN] + [Bypass] [*] All bypasses will be cleared.