User`s guide

DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 11
4.0 Hardware Layout Example
Armed
St at u s
Power
Fir e
1 23
456
789
0
*
#
On
No
Ent r y
System
Re s e t
Bypass
Only
Peri m eter
Off
Per i m e t e r
Supe rv is or y
Bell Silenced
Troubl e
123 456 7 8
®
DS7488 Octal
Relay Board
DS7400Xi
+–+–
Power Bus
DS7420i Dual Phone
Line/Bell Supervision
Module
DS7447/DS7447E and DS7445/DS7445i
Keypads
R
DS7450/52 Series Contacts, DS7460 Input Module
s,
DS7465 Input/Output Modules, MX540, MX775,
MX794, MX835, MX934, MX938, and MX950 motio
n
detectors and MX280 Series Smoke Detectors
DS7430
Keypads #11 - #15 must be connected to
the Options Bus. Keypads #1 - #10 must
be connected to the Keypad Bus.
Note:
Ensure at least 1/4" separation
between battery wires and all
other cabling.
Armed
St at u s
Po w er
Fir e
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
Armed
Stat us
Powe r
Fire
1 23
456
789
0
*
#
On
No
Entry
Sys te m
Reset
Byp ass
Only
Per i me t e r
Off
Armed
St at u s
Po w er
Fir e
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
Armed
St at u s
Po w er
Fir e
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
Armed
St at u s
Po w er
Fir e
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
Armed
St at u s
Power
Fir e
1 23
456
789
0
*
#
On
No
Ent r y
System
Re s e t
Bypass
Only
Peri m eter
Off
Per i m e t e r
Supe rv is or y
Bell Silenced
Troubl e
123 456 7 8
®
Armed
St at u s
Power
Fir e
1 23
456
789
0
*
#
On
No
Ent r y
System
Re s e t
Bypass
Only
Peri m eter
Off
Per i m e t e r
Supe rv is or y
Bell Silenced
Troubl e
123 456 7 8
®
B
G
Y
–+
Option
Bus
Battery
Bell Output
Auxiliary
Out put
+
++
+
+
G
R
B
1
2
3
4
5
6
7
8
9
10
Y
1 12 13 1 4 15 16 17 18 1 9 20 21 22 23 24 25 2 6 27 28
Battery Battery
RF3222 120-Zone
Wireless Receivers
Wireless Sensors
RTRT TTRR TRTR
DS7432 8-Input
Remote Modules
47kΩ
Dry contact inputs
+
+
12345678
POWER BUS
+
+
123 45678
POWER BUS
+
+
12345678
POWER BUS
+–+
123 4567 8
POWER BUS
1234
5
2G
1
-
+
BUS
NO
+
1
2
3
C
NC
DS7416i
Communications
Module
EOL
Up to 15 keypads may be used. Keypads #1 - #10 connect to the Keypad Bus and keypads #11 - #15
connect to the Option Bus. One keypad must be designated as keypad #1 and connected to the Keypad
Bus. See the DS7447/DS7447E, DS7445/DS7445i, and DS7448 Installation Instructions for further details.
A DS7420i (Dual Phone Line/Bell Supervision Module) may be connected to the Control Panel, and
placed within the enclosure. Connect to the Options Bus of the control panel. See the DS7420i Installation
Instructions for further details.
A DS7430 or a DS7436 (Multiplex Expansion Module) may be connected to the control panel via the
expansion port. This will allow for the connection of additional zones via the Options Bus. See the DS7430
or DS7436 Installation Instructions for further details.
Up to 2 DS7488s (Octal Relay Modules) may be connected to the Control Panel, and placed within the
enclosure. Connect to the Options Bus of the Control Panel. This provides an additional 8 Form “C”
relay outputs for the Control Panel. See the DS7488 Installation Instructions for further details.
A DS7416i Advanced Radio Communications Module may be connected to the Control Panel via the Options
Bus. This allows for connection to a radio network.
Up to 248 zones are available for the connection of Single, Multiple, Input/Output, and Multiplex devices.
Up to 112 wireless zones (137-248) are also available.
Up to 2 RF3222 (120-Zone Wireless Receivers) may be connected to the DS7430 or DS7436. Connect to
the Power and Bus terminals of the Multiplex Expansion Module. This allows for the monitoring of wireless
detectors.
Up to 30 DS7432s (8-Input Remote Modules) may be connected to the DS7430 or DS7436. Connect to the
Power and Bus Terminals of the Multiplex Expansion Module. This allows for a means of addressing up to
240 input loops of conventional contacts to the Control Panel. See the DS7432 Installation Instructions for
further details.
1 23
456
789
0
*
#
On
No
Entry
Sys t em
Reset
Byp ass
Only
Per i me t e r
Of f
TEST WEEKLY
12345 67 8
910111213
14 15 16
Armed
Status
Power
Fire
Pe ri met e r
Supervisory
Bell Silenced
Trou bl e
1 23
456
789
0
*
#
On
No
Entry
Sys t em
Reset
Byp ass
Only
Per i me t e r
Of f
TEST WEEKLY
12345 67 8
910111213 141516
Armed
Status
Power
Fire
Pe ri met e r
Supervisory
Bell Silenced
Trou bl e
1 23
456
789
0
*
#
On
No
Entry
Sys t em
Reset
Byp ass
Only
Per i me t e r
Of f
TEST WEEKLY
12345 67 8
91011
12 13 14 15 16
Armed
Status
Power
Fire
Pe ri met e r
Supervisory
Bell Silenced
Trou bl e